MST Locate All articles
Logistics & Fulfilment

Keys, Codes and Custody: A Controlled Register for Site Access

MST Locate
Keys, Codes and Custody: A Controlled Register for Site Access

Photo: Francisclarke, CC BY-SA 4.0, via Wikimedia Commons

The Quiet Risk at the Gate

For many small UK sites, access is not controlled by a gatehouse or a security team. It is controlled by a handful of people who know the padlock combination, a key safe that has not been reviewed since it was installed, and a courier instruction that has been forwarded so many times that nobody is certain which version is current. The arrangement works well enough on an ordinary day. It becomes a liability when a member of staff leaves, a haulier changes subcontractor, or a one-off delivery arrives outside normal hours.

The objective is not to make access difficult. It is to make it predictable, accountable and easy to withdraw. Delivery credentials are operational assets, and they should be treated with the same discipline as a fuel card or a company bank mandate: issued deliberately, recorded accurately and revoked promptly.

Start With a Single Credential Register

A credential register does not need to be elaborate. A shared spreadsheet with restricted edit rights is sufficient for most SMEs, provided it is kept current and reviewed at fixed intervals. The register should list every means by which someone can enter the site or collect from it: physical keys, fobs, key safe combinations, padlock codes, gate codes, alarm codes where relevant, and temporary instructions such as “call this number on arrival” or “report to the side door between 07:00 and 09:00”.

Each entry should record the credential type, its identifier or location, who holds it, the date it was issued, the purpose or scope, and the date it is due for review. A named custodian should be responsible for the register. That person does not need to hold every key, but they should know who does and why.

The register should also distinguish between permanent credentials and temporary ones. A fob issued to a longstanding cleaner belongs in a different category from a gate code shared with a courier for a single pallet collection. Mixing the two is how temporary access becomes permanent by accident.

Short-Life Codes for One-Off Deliveries

One-off deliveries are a common weak point. A supplier needs access on a Saturday morning, so a member of staff sends the usual gate code in a text message. The delivery is completed, but the code remains in circulation. Over time, the site has effectively published its access arrangements to a wide network of drivers, subcontractors and messaging groups.

Where the equipment allows, use a short-life code: one that is valid for a defined window, ideally for a single use or a single day. If the site relies on a mechanical padlock, the practical alternative is a temporary code change before and after the delivery, or a supervised handover at the gate. Neither is convenient, but both are more controlled than leaving a permanent combination in an unmanaged message thread.

For sites without electronic access control, a sealed key safe with a combination changed after each temporary issue can provide a workable middle ground. The code should be sent to the named driver or haulier contact, not to a general enquiries inbox, and it should be accompanied by a clear expiry instruction. The register should record the issue and the planned revocation on the same day.

Revocation When People and Hauliers Change

Access credentials often outlive the relationship that justified them. A member of staff leaves, a haulier loses the contract, or a contractor finishes a project, but the fob is not returned and the code is not changed. The site continues to rely on the assumption that nobody will use access they no longer need.

A revocation routine should be triggered by three events: the end of employment, the end of a supplier or haulier contract, and the loss of a key or fob. The routine should be simple enough to complete in a single working day. Collect physical items where possible, deactivate electronic credentials, change shared codes if there is any doubt about circulation, update the register, and confirm the change to the people who need to know.

It is worth naming a deputy custodian so that the routine does not stall during annual leave or sick leave. The deputy should have access to the register but not necessarily to every credential. The aim is continuity of control, not a second informal copy of every code.

Signage That Helps Without Exposing the Site

Drivers need clear instructions, but a sign at the gate is a public document. It should not display the gate code, the key safe combination or any detail that would allow an unauthorised person to enter. Instead, it should tell the driver what to do: report to reception, call the number on the delivery note, use the intercom, or wait in the marked bay. The specific credential should be provided separately to the named driver or haulier.

Signage should also carry a version date and a contact number for access queries. If the instructions change, the sign should change with them. A laminated notice that has faded in the sun and still refers to a former site contact is worse than no notice at all, because it encourages drivers to improvise.

Review, Record and Keep It Boring

A quarterly review is enough for most small sites. Check that every credential in the register is still needed, that every holder is still entitled to it, and that every temporary issue has been closed. Look for credentials that have no recorded owner, codes that have not changed since the last review, and instructions that exist only in someone’s memory.

The best access control is unremarkable. Drivers know where to go, staff know who holds what, and changes are recorded without drama. By treating keys, fobs and codes as controlled assets rather than background details, a small UK site can keep its gates open to the right people and closed to everyone else.

All Articles

Related Articles

Salt Before Sunrise: Winter-Proofing a Small Site's Deliveries

Salt Before Sunrise: Winter-Proofing a Small Site's Deliveries

Measuring the Road Before the Round: A Physical Limits Register for Small UK Van Fleets

Measuring the Road Before the Round: A Physical Limits Register for Small UK Van Fleets

The One-Page Yard Standard: A Durable Brief for Site Delivery Restrictions

The One-Page Yard Standard: A Durable Brief for Site Delivery Restrictions