Electric vans are often presented as a straightforward swap: take delivery, plug in overnight, repeat. For many UK SMEs, the reality is less tidy. A small yard may have an electricity supply sized for an office, a workshop and a few external lights, with little apparent headroom for several vehicles charging at once. The constraint is rarely the van itself. It is the site.

The sensible sequence is therefore watts before wheels. Establish what power the yard can safely provide, then design a charging pattern and a commercial arrangement around that limit. Approached in that order, electrification can remain an operational project rather than a costly surprise.

Begin with the supply, not the showroom

Before requesting quotations for vehicles or chargers, gather the site's electrical facts. Recent electricity bills should identify the meter point administration number, the agreed supply capacity and the tariff structure. A qualified electrician can then carry out a load study covering existing demand, spare capacity, earthing arrangements and the practical route for new connections. Fuse ratings alone are not a reliable guide to available capacity.

It is also worth separating capacity from energy. A site may consume modest amounts of electricity over a week but still lack the capacity to support several chargers at peak times. Conversely, a site with a reasonable supply may be able to accommodate charging if demand is managed carefully. The distribution network operator should be consulted early if an upgrade appears necessary, because lead times and costs can alter the business case.

For a small fleet, the key question is not whether the yard can replicate a depot-scale charging hub. It is whether the site can deliver enough energy during the hours the vans are actually parked. That is a narrower and often more achievable test.

Design the overnight window around the delivery day

Charging should be planned around return times, first departures and route lengths, not around a nominal eight-hour night. Telematics data can show when vans come back, how much energy they use and which vehicles leave first. A simple charging schedule can then prioritise the vans that need the most energy before the earliest departures.

Not every van needs a dedicated high-power charger. Many light commercial vehicles can recover a useful day's range from a 7kW connection over a normal overnight stop. Where the supply is tight, load management can stagger charging so the site stays within its agreed capacity. Shared chargers, timed starts and dynamic balancing are often more sensible than assuming every bay must charge at full rate simultaneously.

Cold weather, payload and route profile all affect consumption, so the schedule should include a margin rather than relying on best-case figures. A pilot period with one or two vans will reveal whether the planned window is realistic. If drivers routinely return late or leave early, the charging plan needs to reflect that behaviour before the rest of the fleet is committed.

Make the lease work as hard as the charger

In rented premises, the electrical work is only part of the project. The lease may require landlord consent for alterations, external equipment, cable routes, trenching, bollards or signage. Reinstatement obligations should be understood before any charger is fixed to a wall or floor. Where the yard is shared, metering and cost allocation need to be agreed in writing so that electricity used by the fleet is not quietly absorbed into service charges.

It is also prudent to establish who owns the charging equipment, who maintains it and what happens if the business relocates. Removable or modular equipment can reduce the risk of leaving value behind. If a new supply or upgraded connection is required, the lease should clarify responsibility for obtaining consents and recovering costs. These points are easier to negotiate before the vehicles arrive than after the first invoice.

Use public charging as a planned second line

Public charging is often treated as an emergency option. For a power-limited yard, it is better understood as part of the operating model. Destination charging near regular stops, retail or leisure locations with longer dwell times, and a small number of reliable rapid sites can cover gaps without forcing the depot to carry the entire load.

That said, public charging should be mapped route by route. Drivers need to know which points are accessible for a van, which accounts or roaming arrangements work, and what to do if a bay is occupied or out of service. Rapid charging is useful for exceptions, but routine reliance on it tends to increase cost and reduce control. A short fallback list for each regular route is more practical than a single assumed backup point.

Test the plan before it becomes the plan

A pilot of one or two vehicles, run alongside existing operations, will expose the weak points: queueing at the charger, unrealistic departure times, driver confusion over accounts or unexpected energy use on longer routes. Review the data after several weeks and adjust the schedule, charger allocation and public charging guidance.

The switch to electric vans can work well for small UK sites, but only when the power supply, the delivery timetable and the lease are treated as one operational question. Starting with watts rather than wheels keeps the project grounded in what the yard can actually support, and leaves less room for the delivery day to break quietly after the vehicles have arrived.

All Articles

Related Articles

Before the First Pallet Lands: A Pre-Lease Delivery Access Audit for UK Sites

Before the First Pallet Lands: A Pre-Lease Delivery Access Audit for UK Sites

When the Cones Arrive: A Four-Week Countdown to Roadworks-Proof a Small Site

When the Cones Arrive: A Four-Week Countdown to Roadworks-Proof a Small Site

Closing the Loop: Making Returns Pay Their Way Through Smarter Site and Route Choices

Closing the Loop: Making Returns Pay Their Way Through Smarter Site and Route Choices